BCXJW - 1209 TURBINE LUBRICANT;P.CODE:341209-01209

Product Identification

Product ID:1209 TURBINE LUBRICANT;P.CODE:341209-01209
MSDS Date:09/10/1987
FSC:9150
NIIN:00-072-8039
MSDS Number: BCXJW

Responsible Party
EXXON CO.USA,A DIV OF EXXON CORP.
800 BELL STREET
HOUSTON, TX 77252-2180
US

Emergency Phone: 713-656-3424

Info Phone: 713-656-2443/5949

Cage: JO983

Contractor
EXXON COMPANY U.S.A.
2180 HOUSTON, TX 77252-2180 US

Telephone: 713-656-5949 / 713-656-3424

Cage: 29700

Ingredients

LUBRICATING OIL BASE STOCK (64742-54-7 OR 64742-65-0)

Fraction By Weight: >95.0%


TRIORTHOCRESYL PHOSPHATE

CAS: 78-30-8

RTECS: TD0350000

Fraction By Weight: <2.0%

OSHA PEL S, 0.1 MG/M3

ACGIH TLV: S, 0.1 MG/M3; 9192


PROPRIETARY ADDITIVES

Fraction By Weight: < 1.0%

Hazards

LD50 LC50 Mixture:ORAL RAT 5G/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:ACUTE:IRRITATION OF EYES,SKIN OR LUNG
IRRITATION DUE TO OIL MIST/VAPORS. CHRONIC:SKIN IRRITATION OR
DERMATITIS.
Effects of Overexposure:SEE HEALTH HAZARDS DATA.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS MAY BE
WORSEN.

First Aid

First Aid:SKIN AND EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR 15
MINUTES,CALL A PHYSICIAN. INHALATION:REMOVE TO FRESH AIR;CALL A
PHYSICIAN. INGESTION:DO NOT INDUCE VOMITING.CALL A DOCTOR
IMMEDIATELY.

Fire Fighting

Flash Point Method:COC
Flash Point:399F/204C
Autoignition Temp:Autoignition Temp Text:>500F
Lower Limits:0.9
Upper Limits:7.0
Extinguishing Media:FOAM,WATER SPRAY,DRY CHEMICAL,CO*2
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA IN AN ENCLOSED
AREA.
Unusual Fire/Explosion Hazard:DECOMPOSITION PRODUCTS LIKE SMOKE OR
FUMES,CO GAS,SULFUR-OXIDES OR ALDEHYDES.

Accidental Release

Spill Release Procedures:USE PROPER PERSONAL PROTECTION;RECOVER FREE
LIQUID;USE SUITABLE ABSORBENT MATERIAL AND COLLECT FOR PROPER
DISPOSAL.

Handling

Handling and Storage Precautions:STORE IN COOL,DRY AND WELL VENTILATED
AREA.KEEP AWAY FROM HEAT,OPEN FLAMES.KEEP CONTAINER CLOSED WHEN NOT
IN USE.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR ORGANIC
VAPORS/MIST IF ABOVE TLV/PEL.
Ventilation:LOCAL EXHAUST TO MAINTAIN TLV/PEL
Protective Gloves:CHEMICAL-RESISTANT
Eye Protection:CHEMICAL GOGGLES/SIDE SHIELD
Other Protective Equipment:IMPERVIOUS CLOTHING,EYE WASH
Work Hygienic Practices:AVOID CONTACT WITH EYES AND SKIN;DO NOT BREATHE
VAPORS/MIST;WASH THOROUGHLY AFTER EACH USE.
Supplemental Safety and Health
MSDS RECEIVED BY DGSC:APRIL 29,1988.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:555F/291C
Melt/Freeze Pt:M.P/F.P Text:14F/-10C
Vapor Pres:< 0.01 MMH
Vapor Density:> 5.0
Spec Gravity:0.88
pH:NEUTRL
Viscosity:77 CST
Evaporation Rate & Reference:< 0.01 (N-BUTYL ACETATE=1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID,LIGHT YELLOW COLOR
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS
Stability Condition to Avoid:EXTREME HEAT,OPEN FLAMES
Hazardous Decomposition Products:CO GAS,SULFUR OXIDES OR ALDEHYDES

Disposal

Waste Disposal Methods:DISPOSE OF COLLECTED MATERIAL IN ACCORDANCE WITH
LOCAL,STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.